Circulation Chillers for Variable Use in Laboratory, Mini-Plant and Production for Temperatures From -20 Up to 40°C

LAUDA Variocool circulation chillers offer a broad performance spectrum for demanding temperature control tasks, The color TFT screen makes operation easy. A USB interface and an alarm contact are integrated as standard features. Additional interfaces are available as accessories. They are located in the front of the device, allowing for easy access.

The circulation chillers with their multitude of operations are very well suited to a number of different areas of application Optional pumps, for eample, enable higher pressures anf flows. Optional heating units, which are adapted to the cooling capacitym enable the quick heating of the connected application when needed.

Numerous Options, Compact Design, Easy Operation

Variocool circulation chillers function in an operating temperature range of -20 to 40°C. Optional heaters can be added to increase the maximum temperature to 80°C. For greater pressure requirements, optional pumps are available with the VC 1200 version or higher. All models are available as water-cooled versions (W) except VC 600. The compact dimensions of the models from VC 600 to VC 2000 (W) allows them to be placed under the laboratory table.

VC 3000 and VC 5000 offer cooling capacities of 3 and 5 kW, and are available with options such as outdoor-installation and sound absorption. VC 7000 and VC 10000 are high efficient tower design circulation chilolers are available as water cooled versions (W). High cooling capacities and flexible options such as additonal heating and pump power add to the devices’ area of application.

Available Models

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.05 ±K
Cooling output at 20°C1.2 kW
Pump pressure max.0.9 bar
Pump flow28 L/min

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.05 ±K
Cooling output at 20°C1.2 kW
Pump pressure max.0.9 bar
Pump flow28 L/min

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.05 ±K
Cooling output at 20°C2.0 kW
Pump pressure max.0.9 bar
Pump flow28 L/min

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.05 ±K
Cooling output at 20°C2.0 kW
Pump pressure max.0.9 bar
Pump flow28 L/min

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.05 ±K
Cooling output at 20°C3.0 kW
Pump pressure max.3.2 bar
Pump flow37 L/min

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.05 ±K
Cooling output at 20°C3.0 kW
Pump pressure max.3.2 bar
Pump flow37 L/min

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.05 ±K
Cooling output at 20°C5.0 kW
Pump pressure max.3.2 bar
Pump flow37 L/min

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.05 ±K
Cooling output at 20°C5.0 kW
Pump pressure max.3.2 bar
Pump flow37 L/min

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.1 ±K
Cooling output at 20°C7.0 kW
Pump pressure max.3.2 bar
Pump flow37 L/min

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.1 ±K
Cooling output at 20°C7.0 kW
Pump pressure max.3.2 bar
Pump flow37 L/min

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.1 ±K
Cooling output at 20°C10.0 kW
Pump pressure max.3.2 bar
Pump flow37 L/min

Technical Specifications

Working temperature range-20…40°C -20…80°C (with heater)
Temperature stability0.1 ±K
Cooling output at 20°C10.0 kW
Pump pressure max.3.2 bar
Pump flow37 L/min

Key Features

  • Electronic expansion valves reduce energy consumption and operating cost  
  • Compact design saves valuable laboratory space  
  • Color TFT display screen and membrane keyboard allows easy and intuitive operation  
  • Electronic fill gauge on the display and low level alarm ensures early detection of insufficient fluid  
  • Flexible customization to all applications with optional accessories (power pumps, heaters, outdoor installation . sound absorption)  
  • Easily removable front grill for easy cleaning of condenser  
  • Tower design for larger models reduces footprint  

Variocool Overview

Key Industries

  • Aerospace
  • Agriculture
  • Automotive
  • Biopharmaceutical and Biotechnology
  • Chemical
  • Construction
  • Cosmetics & Personal Care
  • Defense
  • Die & Mould
  • Education & Academics
  • Electronics
  • Energy
  • Environmental
  • Food & Beverage
  • Luxury
  • Machinery & Manufacturing
  • Medical
  • Mining & Minerals
  • Oil & Gas
  • Optical
  • Paper & Wood
  • Pharmaceutical
  • Polymers, Plastics and Rubbers
  • Powders & Pigments / Coating
  • Railway
  • Semiconductor, Solar & Electronics
  • Service
  • Textile
  • Wholesale & Retail

Brand

Lauda

We are LAUDA – The world leader in precise temperature control. Our Constant temperature equipment and Heating and cooling systems are at the heart of many applications. As a full-service provider we guarantee the optimum temperature in research, production and quality control. We are the trusted partner, particularly in the fields of automotive, chemical/ pharmaceutical, semiconductor and laboratory/ medical industries. For over 60 years we have been inspiring our customers with our competent consulting and innovative, environmentally-friendly concepts, anew every day – globally.

test block for Laos

Your download – just a few steps away

Please enter your details here:

test

Contact us